UV-VIS

Spectrometer System

  • Design-in platform with light source and spectrometer module

  • Broadband light sources include halogen, deuterium-halogen, and Xenon flash lamps

  • High-performance Zeiss spectrometers covering various ranges 
    from 190 nm to 2150 nm 

  • Permanently wavelength calibrated

  • Electrical and optical multiplexer technology allowing up to 8 channels for simultaneous data collection

  • Various electronic interfaces including PCIe, USB, Ethernet 

  • Full process-capable communication PCS interfaces including OPC, Profibus, and Analog/Digital

MMS UV-VIS

  • Extremely compact design

  • High repeatability

  • High throughput with fiber bundle 600 m cross section converter

  • Hamamatsu diode array, 256 pixel

  • The diode array is coated with dielectric cut-off filters to suppress the 2nd order light

  • Permanently Calibrated, temperature induced drift ≤ 0.01 nm /K

  • Holographically blazed, flat field gratings

  • N.A. 0.22

  • Spectral Range: 190-1100 nm

  • Resolution ∆λFWHM ≈ 10 nm

  • Wavelength accuracy: 0.5 nm

  • Low Stray Light

  • Dimensions L x W x H: 70 x 50 x 40 mm (with case)

CGS UV-VIS-NIR

  • High Sensitivity

  • High Resolution

  • Fast Measurement

  • Hamamatsu linear back-thinned CCD, 2048 pixel

  • Breathing design, all optical components mounted to a housing made of aluminum

  • Permanently Calibrated

  • SMA fiber connector, 600 m mono-fiber interface

  • Spectral Range: 190-1000 nm

  • Resolution ∆λFWHM ≈ 2.2 – 2.5 nm

  • Low Stray Light

  • Dimensions L x W x H: 78 x 30 x 75 mm

MCS-CCD UV-VIS-NIR

  • High sensitivity to UV light

  • High throughput with fiber bundle 600 m cross section converter

  • Hamamatsu S7031, back-thinned, TE-cooled CCD, 2D: 1044 x 64pixel

  • Fan-cooled heat sink

  • The diode array is coated with dielectric cut-off filters to suppress the 2nd and the 3rd order light

  • Permanently Calibrated, temperature induced drift ≤ 0.009 nm /K

  • Holographically blazed, flat field gratings

  • N.A. 0.22

  • Spectral Range: 190-1000 nm

  • Resolution ∆λFWHM ≈ 3 – 4 nm

  • Wavelength accuracy: 0.5 nm

  • Low Stray Light

  • Dimensions L x W x H: 198 x 68 x 122 mm (long Cross Section Converter)

MCS-PDA UV-VIS-NIR

  • High Dynamic Range: 12000:1

  • High throughput with fiber bundle 600 m cross section converter to achieve the theoretical limit of light intensity

  • Hamamatsu S3904-1024Q, 1024 pixel

  • The diode array is coated with dielectric cut-off filters to suppress the 2nd and the 3rd order light

  • Permanently Calibrated, temperature induced drift ≤ 0.009 nm /K

  • Holographically blazed, flat field gratings

  • Spectral Range: 190-1000 nm

  • Resolution ∆λFWHM ≈ 3 – 4 nm

  • Wavelength accuracy: 0.5 nm

  • Low Stray Light

  • Dimensions L x W x H: 160.3 x 62 x 122.2 mm